The SWIK Solution
Home Care
You can use SWIK at home for simple, safe, and continuous removal of oral secretions.
The SWIK Solution
Home Care
SWIK is the ONLY hands-free and continuous oral suction device available. You can use SWIK at home for simple, safe, and continuous removal of oral secretions.
Up to 15 Million Adults in the United States are Affected by Swallowing Disorders.
You are not alone. SWIK Medical Solutions is here to help.
Better Quality of Life for Patients, Peace of Mind for Caregivers
SWIK replaces traditional disposable suction devices for a wide range of patients, including those who are ventilated, suffering from head and neck cancers or neurodegenerative diseases.
Constant intervention required by currently available oral suction devices and methodologies can be burdensome for caregivers of those with difficulty swallowing.
No More Swabs or Bibs
Traditional oral suction equipment for patients who can’t swallow provides short-term relief at high costs. The standard suction devices are used intermittently and manually, which can cause damage to the mouth’s soft tissue and other serious problems.
“I want patients to know there is hope. With SWIK, a better quality of life is possible for those with swallowing disorders.”
How To Use SWIK
SWIK Setup at a Glance
Watch this short video to see how to use SWIK or view the images below and follow the step-by-step instructions.
Once you remove SWIK and the extension tubing from the package, follow these simple steps:
Attach the 56 inch Extension Tubing’s blue universal pump connector...
Saturate wicking foam with potable water and gently squeeze to prevent...
Insert the 16 inch Catheter luer connector into the 56 inch...
Hold the device with the tubing pointing up-ward. The tubing is pre-set...
To adjust the position of the tubing on the wicking foam, pull the wicking foam taut and...
Insert the wicking foam between the patient's lower lip and gumline. Wicking foam does not...
Check to ensure the wicking foam is not twisted and is securely in place...
Review pump’s Owner’s Manual for proper set-up and instructions for use...
- Attach the 56 inch Extension Tubing’s blue universal pump connector to the canister on the pump. Pump should be off while attaching. Ensure the connector is securely fastened onto the canister.
- Saturate wicking foam with potable water and gently squeeze to prevent dripping. Wetting the wicking foam makes it more comfortable and helps the wicking process begin.
- Insert the 16 inch Catheter luer connector into the 56 inch Extension Tubing luer connector and gently twist to lock.
- Hold the device with the tubing pointing up-ward. The tubing is pre-set to the patient’s left side. Place tubing over the patient’s left ear, be sure to give a little slack to allow the patient to turn their head from side to side. To change sides, see next instruction.
- To adjust the position of the tubing on the wicking foam, pull the wicking foam taut and gently slide the tubing across the wicking foam. When adjusting, DO NOT slide tubing more than 1/2 inch beyond the end of the wicking foam. DO NOT remove wicking foam from tubing.
- Insert the wicking foam between the patient’s lower lip and gumline. Wicking foam does not cross the biting surface. Push wicking foam deep into the gumline, using fingertips or a long cotton swab, start-ing in the middle and working evenly on both sides along the jawline, reaching the back teeth.
- Check to ensure the wicking foam is not twisted and is securely in place. Check to ensure tubing is not kinked. Secure tubing to face with tape. If using without a pump, remove SWIK® when the wicking foam appears full of secretions, wring out, and reinsert.
- Review pump’s Owner’s Manual for proper set-up and instructions for use. Turn pump on, suggested range is -20 to -40 mmHg. (thick secretions may require higher suction under supervision). Verify suction is functioning by checking that secretions are moving through the tubing. Choose continuous or intermittent settings, based on patient need.
- Turn off the pump and gently remove the device from the patient’s mouth. Turn the pump back on briefly to clear the tube. Disconnect 16 inch Catheter from the 56 inch Extension Tubing and discard.
SWIK is a Helping Hand to Both Caregiver and Patient.
The SWIK device is discreet. Because of its low-profile design, a patient can be supported with continuous suction of oral secretions inside and outside the home while maintaining a sense of dignity.
Each SWIK device may be used for up to 12 hours without intervention. Independence becomes more possible with SWIK, the portable, hands-free solution.
Easy to Use, Simple to Connect.
SWIK includes a universal adapter that connects to wall mount or portable pumps. When using SWIK you must use a pump that is capable of running 24/7. See the Get SWIK page for pump information.
If you need assistance with finding and/or selecting an appropriate pump, the SWIK team is here to help. Just reach out using one of our contact methods.
In this short video, Sabrina shares her experiences living with ALS, specifically the inability to swallow and the embarrassment it causes. Patients with ALS like Sabrina can benefit from SWIK’s continuous, hands-free, and comfortable management of secretions.